Back to Blog
York ycal low ambient kit6/3/2023 ![]() Voltages as low as 50 volts may cause death. 2 JOHNSON CONTROLSģ FORM RP4 (809) TABLE OF CONTENTS PAGE UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATA.4 EVAPORATOR HEAT EXCHANGER AND RELATED COMPONENTS.5 CONDENSER COILS CONDENSER COIL COMPONENTS.8 FAN FAN COMPONENTS.2 PIPING REFRIGERANT PIPING COMPONENTS.4 COMPRESSOR COMPRESSOR.24 CONTROL AND POWER PANEL CONTROL PANEL AND POWER PANEL CONFIGURATIONS.28 CONTROL PANEL AND POWER PANEL COMPONENTS.29 CONTROL WIRING HARNESSES.57 SENSOR WIRING HARNESSES.58 TEMPERATURE SENSORS AND TRANUCERS.60 TRANUCER AND THERMISTOR WIRE HARNESS CONNECTORS.62 ENCLOSURE UNIT ENCLOSURE COMPONENTS.64 CHILLER OPTIONS VIBRATOR ISOLATORS.68 CHILLER OPTIONS.69 PUMP PACKAGE KIT OPTIONS.70 ENCLOSURE KIT OPTIONS.82 OPTIVIEW REMOTE CONTROL CENTER.88 REMOTE CURRENT/TEMPERATURE RESET PARTS BREAKDOWN.89 RECOMMENDED SPARE PARTS.90 JOHNSON CONTROLS 3Ĥ FORM RP4 (809) UNIT NOMENCLATURE NAMEPLATE ENGINEERING DATA BASIC PART NUMBER YCAL006EC28XDA BASE PRODUCT TYPE NOMINAL CAPACITY UNIT DESIGNATOR REFRIGERANT VOLTAGE/STARTER DESIGN/DEVELOPMENT LEVEL Y : YORK # Tons/Kw E High Efficiency C :R-22 7 :200/3/60 D C : Chiller :230/3/60 A : Air Cooled L : Scroll to :380/3/60 :460/3/60 A 5 0 :385-45/3/ :575/3/60 X :Across the Line :Design Series D :Engineering Change or PIN Level PART NUMBER LETTER CODES POWER FIELD CONTROLS FIELD COMPRESSOR / PIPING FIELD S S B X D X T C : SP Terminal Block L : SP NF Disconnect Switch H : SP Circuit Breaker A : Transformer 5/24V (factory) : Power Factor Capacitor MP = Multiple Point SP = NFDS = Non-Fused Disconnect Switch TB = Terminal Block Ser. = Service CB = Circuit Breaker M T S F G R L C O S : Low Ambient Kit (factory) : High Ambient Kit (factory) : Both Low / High Ambient (factory) : ISN Microgateway : BAS/EMS Temp. Reset / Offset : Spanish LCD & Keypad Display : French LCD & Keypad Display : German LCD & Keypad Display # T # S : Disch Press Transducers / Readout C S B : N. The chiller has suction-gas cooled, hermetic, scroll compressors.American Safety Code (cu.l./cetl) : Motor Current Module : OptiView Remote Control Panel : Sequence Control & Automatic Lead Transfer 2 :Low Temp. Units are designed in accordance with NFPA 70 (National Electric Code),ASHRAE/ANSI 15 Safety code for mechanical refrigeration,ASME, Listed and labeled with Intertek Testing Services (ETL) and rated in accordance with ARI Standard 550/590-2003. Corrosion resistant wire mesh panels are added to protect the condenser coil from incidental damage and restrict unauthorized access to internal components. The unit structure is heavy-gauge, galvanized steel.This galvanized steel is coated with baked-on powder paint, which, when subjected to ASTM B117 1000 hour, salt spray testing, yields a minimum ASTM 1654 rating of “6”. After assembly, a complete operational test is performed with water flowing through the cooler to assure that the refrigeration circuit operates correctly. ![]() The unit is pressure-tested, evacuated, and fully charged with Refrigerant-22 (HCFC-22) and includes an initial oil charge. The 47 - 60 Ton (165 - 210 kW) YCAL models are shipped complete from the factory ready for installation and use. Power Wiring.Ĭontrol Wiring.Īpplication Data. Isolator Details (cont'd).Įlectrical Data.Įlectrical Data - 60Hz.Įlectrical Data - 50Hz. Sound Data.ĭimensions - YCAL0041 (English).ĭimensions - YCAL0045 (English).ĭimensions - YCAL0051 (English).ĭimensions - YCAL0055EC - (English).ĭimensions - YCAL0061 (English).ĭimensions - YCAL0065 (English).ĭimensions - YCAL0041 (SI). Part Load Ratings - R-22 (English Units). Ratings - R-22 (50Hz - English Units) - Cont. Ratings - R-22 (60Hz - English Units) - Cont. Ratings - R-22 (50Hz - English Units) - Cont.Ratings - R-22 (60Hz - English Units) - Cont. ![]()
0 Comments
Read More
Leave a Reply. |